Caramatic BasicOne type EN61
for connection to gas cylinders to regulate the pressure to the nominal pressure of the gas equipment
for connection to gas cylinders to regulate the pressure to the nominal pressure of the gas equipment
- with pressure relief valve PRV
- vent plug that also prevents moisture, such as rainwater, getting inside the regulator
- version with extended inlet connector, 90° outlet suitable for VW camper vans with Westfalia fit-out
- EC type approval according to PED
- maximum permissible pressure: PS 16 bar
In the German DVGW worksheet G 607 for LPG systems in occupied leisure vehicles and for living purposes in other road vehicles, it is prescribed in the chapter for operation and testing that pressure regulators are to be replaced 10 years after the date of manufacture at the latest. If the working pressure of the system is 30 mbar, pursuant to G 607, a regulator according to EN 16129, annex D (e.g. part no. 01 280 10) is to be used in the event of a replacement. For LPG systems in vehicles with a working pressure of 50 mbar, a non-compliance permit applies. There is no obligation to convert to 30 mbar.